GLUED FLOORING - DIVINO
Ignore product information
1 of 33

GLUED FLOORING - DIVINO

Standard price
25,00€ m²
Standard price
Price list
25,00€ m²
Taxes included. Shipping costs calculated at checkout.

Texas Oak 82231

Format: Blade

MODEL
subtotal
Taxes included. Shipping costs calculated at checkout.
View the collection
Texas Oak 82231 Adhesive Vinyl Plank
California Oak 81439 Adhesive Vinyl Plank
California Oak 81209 Adhesive Vinyl Plank
California Oak 81811 Adhesive Vinyl Plank
Texas Oak 82201 Adhesive Vinyl Plank
Texas Oak 82941 Adhesive Vinyl Plank
Texas Oak 82871 Adhesive Vinyl Plank
Texas Oak 82991 Adhesive Vinyl Plank
Major Oak 53256 Adhesive Vinyl Plank
Major Oak 53452 Adhesive Vinyl Plank
Major Oak 53232 Adhesive Vinyl Plank
Barley Oak 84227 Adhesive Vinyl Plank
Barley Oak 84312 Adhesive Vinyl Plank
Tucker Oak 85246 Adhesive Vinyl Plank
Tucker Oak 85926 Adhesive Vinyl Plank
Tucker Oak 85296 Adhesive Vinyl Plank
Tucker Oak 85236 Adhesive Vinyl Plank
Kentucky Oak 83113 Vinyl Plank for Adhesive Installation
Kentucky Oak 83273 Adhesive Vinyl Plank
Kentucky Oak 83853 Adhesive Vinyl Plank
Marmara 46595 Adhesive Vinyl Tile
Marmara 46506 Adhesive Vinyl Tile
Marmara 46537 Adhesive Vinyl Tile
Musseta 46531 Adhesive Vinyl Tile
Musseta 46574 Adhesive Vinyl Tile
Musseta 46523 Adhesive Vinyl Tile
Barley Oak 84227 Adhesive Vinyl Plank
Barley Oak 84312 Adhesive Vinyl Plank
Major Oak 53256 Adhesive Vinyl Plank
Kentucky Oak 83273 Adhesive Vinyl Plank
Kentucky Oak 83853 Adhesive Vinyl Plank
Marmara 46537 Adhesive Vinyl Tile
Marmara 46506 Square Vinyl Tile for Adhesive Installation

Description

SOL COLLÉ features vinyl planks and tiles (LVT) from the Divino Dryback line, manufactured in Belgium. Each piece is fully glued to a hard, level, and dry subfloor: this is the thinnest installation option—just 2.5 mm—making it ideal for renovation projects where headroom is limited.

Its multilayer construction incorporates a double layer of glass fiber, ensuring excellent dimensional stability even when exposed to temperature fluctuations. The 0.55 mm wear layer, protected by the Superguard surface treatment, is resistant to scratches, stains, and casters (25,000 cycles according to ISO 4918).

Wood-look decors with textures that match the pattern, as well as stone-effect decors, available in planks, rectangular tiles, and square tiles. Rated 23 · 33 · 42 for adhesive installation, Bfl-s1 for fire resistance, and A+ for indoor air quality, it is suitable for residential, office, and commercial spaces alike.

DIVINO Adhesive-Backed LVT Flooring: 2.5 mm Vinyl Planks and Tiles
Natural look
Recyclable
Easy to replace

Features

Dimensions of vinyl planks and tiles in the glued, click-lock, and floating installation lines
Dimensions Plank 1320 x 196 mm · Tile 986 x 493 mm · Square tile 493 x 493 mm
Thickness 2.5 mm
Weight 4.06 kg/m²
Material Multilayer compact vinyl, double-layer glass fiber
Wear layer 0.55 mm
Surface Finish Superguard Pride
Usage Class 23 · 33 · 42 (Class 42: full-adhesive installation only)
UPEC Rankings U3 P3 E2 C2 / U3 P3 E1 C2 (CSTB certificate, excluding split-face brick)
Fire Resistance Bfl-s1
Slipperiness R9 – R10 · DS
Acoustics ΔLw 3 dB when installed using an adhesive · 10 dB on a Flex Pro underlayment
Underfloor Heating Compatible — contact temperature ≤ 27 °C · thermal resistance 0.01 m²K/W
Air Quality A+ · M1 · FloorScore · no added formaldehyde
Installation Full-adhesive installation on a hard, flat, and dry surface
Warranty 25 years for residential use · 10 years for commercial use

Compare with another product

Choose two products to see how they differ.

This product

Choose a product

Solid slabs

Perforated slabs

Tatami Mats / Shock-Absorbing Tiles

Vinyl tiles and planks

Vinyl planks and tiles

Glued-down flooring

23 · 33 · 42 (Class 42: full-adhesive installation only)

Plank 1320 x 196 mm · Tile 986 x 493 mm · Square tile 493 x 493 mm

Thickness: 2.5 mm

Starting at €25.00 per square meter

Compare with

Choose a product

Solid slabs

Perforated slabs

Tatami Mats / Shock-Absorbing Tiles

Vinyl tiles and planks

Vinyl planks and tiles

Snap-on base

23 · 33

Plank 1251 x 189 mm · Tile 610 x 303 mm

Thickness: 5 mm (4 mm + 1 mm integrated acoustic underlay)

Starting at €35.00 per square meter

FAQ

What is the difference between glued, click-lock, and floating flooring?

Glued — the planks are fully glued to a hard, level, and dry subfloor. This is the thinnest installation method, the one that best conducts heat from an in-floor heating system, and the only one that meets the highest wear-resistance classes. However, it requires a perfectly prepared subfloor, time for the adhesive to dry, and removal is destructive.

Click-lock — the planks interlock using a click system and rest loosely on the subfloor, without glue. This is a floating installation: it accommodates less-than-perfect subfloors, is quick to install, and can be removed without damage, but requires an expansion gap around the perimeter—at least 5 mm for heated floors—and provides slightly better thermal insulation.

Self-leveling — the planks and tiles are held in place by their own weight and by a lightweight adhesive: tackifying adhesive, adhesive underlayment, or a specialized adhesive depending on the subfloor. The existing floor remains accessible; each element can be lifted and replaced. This installation method is ideal for spaces where it is necessary to work beneath the flooring or replace a tile without interrupting operations.

Which product line should you choose for a business space?

The criterion is not thickness but the usage class (EN ISO 10874 standard): 23 for heavy-duty residential use, 31 to 34 for commercial and retail use, and 41 to 43 for industrial use.

Two key points. The classification also depends on the installation method: at Unilin, the light industrial classification is only certified for fully glued installations. And for offices, it’s the resistance to chairs with casters that matters; this is tested over 25,000 cycles in accordance with ISO 4918.

Do you need to prepare the surface before installation?

Yes, this step determines the floor’s lifespan. The subfloor must be firm, clean, dry, and level: Unilin recommends a maximum unevenness of 2 mm when measured with a 2-meter straightedge. If the unevenness exceeds this, the subfloor must be leveled.

Maximum residual moisture content before installation:

  • cement screed: 2.0% cement content, reduced to 1.8% if it is a heated screed;
  • anhydrite screed: 0.5% CM, 0.3% if heated;
  • wood substrate: 10% moisture content.

A porous surface, or a concrete slab in contact with the ground, requires a primer or a moisture barrier. Installation is possible over tile, old compact PVC, or sound hardwood flooring, provided the joints are filled. Installation is not permitted over flexible flooring—such as carpet, needle-punched flooring, or expanded vinyl—or over an existing floating floor.

Are these floor coverings suitable for in-floor heating?

Yes, all three installation methods are compatible with a water-based floor heating system integrated into the screed. There are two limitations to keep in mind: the surface temperature of the floor must never exceed 27 °C, and the total thermal resistance of the system—including the flooring and underlayment—must remain below 0.15 m²K/W.

The flooring itself accounts for only a small portion of this total—about 0.01 m²K/W when installed without an underlayment—so it is the underlayment for a click-lock installation that must be chosen carefully. A glued floor conducts heat slightly better than a floating floor.

Installation: The heating system should be operational two weeks prior to installation, shut off 24 hours before and during installation, and restarted 48 hours afterward, in increments of no more than 5 °C per day. Cooling is possible if the control system maintains the floor temperature at least 3 °C above the dew point. Electric heating films are only partially compatible; this must be verified on a case-by-case basis.

How do you care for LVT flooring?

For daily cleaning, simply sweep or vacuum, and stains can be removed immediately with a damp cloth. For periodic cleaning, use a microfiber mop wrung out as much as possible and a neutral detergent. When using a floor scrubber: use the red pad and very little water.

Avoid: steam cleaners (not recommended by the manufacturer) and household cleaning products such as dish soap, which leave a film that is difficult to remove.

Three precautions can prevent most damage: felt pads under furniture legs; W-type office chair casters in accordance with EN 12529—never use rubber or latex, including rubber-backed mats, which leave permanent stains on vinyl; and an entry mat at least two steps long, which traps about 70% of dirt.

Can a damaged plank or tile be replaced?

Yes, and that's one of the benefits of LVT: repairs can be made locally, without having to remove the rest of the flooring.

With a floating installation, the tile can be lifted and replaced directly: this is the easiest method for repairs, and the main reason for using this installation method in occupied spaces.

For a glued installation, make a lengthwise cut in the plank using a plunge saw, stopping 10 cm from the ends, then carefully remove the cut material and vacuum the area. Next, cut the grooves in the new plank, apply cold-weld adhesive to the edges, and apply a load of approximately 40 kg for 2 hours.

For a clip-in installation, if the plank is close to a wall, it's faster to unclip the rows up to it; otherwise, use the cutting method described above.

In any case, keep a few samples of each design when you take delivery of the project: manufacturing processes change over time.

Related Products